Models | Power Rating | Input Voltage | Output Voltage | Height (in / mm) | Width (in / mm) | Depth (in / mm) | Weight (lbs / kgs) |
---|---|---|---|---|---|---|---|
Liebert NXC 10kVA | 9KW | 305~477 at full load; 228-477 at 70% load | 380/400/415 (3-phase) or 220/230/240 (1-phase) | / 1240 mm | / 500 mm | / 860 mm | / 115 kgs |
Liebert NXC 15kVA | 13.5kW | 305~477 at full load; 228-477 at 70% load | 380/400/415 (3-phase) or 220/230/240 (1-phase) | / 1240 mm | / 500 mm | / 860 mm | / 115 kgs |
Liebert NXC 20kVA | 18KW | 305~477 at full load; 228-477 at 70% load | 380/400/415 (3-phase) or 220/230/240 (1-phase) | / 1240 mm | / 500 mm | / 860 mm | / 115 kgs |
Liebert NXC 30kVA | 27KW | 305~477 at full load; 228-477 at 70% load | 380/400/415 (3-phase) or 220/230/240 (1-phase) | / 1600 mm | / 600 mm | / 850 mm | / 210 kgs |
Liebert NXC 40kVA | 36KW | 305~477 at full load; 228-477 at 70% load | 380/400/415 (3-phase) or 220/230/240 (1-phase) | / 1600 mm | / 600 mm | / 850 mm | / 210 kgs |
Liebert NXC 60kVA | 54KW | 305~477 at full load; 228-477 at 70% load | 380/400/415 (3-phase) or 220/230/240 (1-phase) | / 1600 mm | / 600 mm | / 850 mm | / 225 kgs |
Greatly reduces operational expenses Virtually eliminates the need for an external battery cabinet and the costs associated with its installation 11% more active power compared to a 0.8 PF UPS Minimizes installation costs by enabling the use of smaller generators, cabling and circuit breakers. Simplifies installation and reduces the need for external devices Wide input parameter range ensure UPS always run on utility power results in prolong battery life The voltage stress of the UPS semiconductors is reduced by half, thus ensuring prolonged life of the critical components Easy replacement in the event of failure significantly reduces the Mean Time To Repair (MTTR) Maximizes battery performance, life and reliability Flexible input performance adjust with generator and eliminate generator over sizing Allows the deployment of the cost effective common battery configuration Ensure trouble free installation and commissioning Progressively transfer load on generator Makes Liebert NXC compatible with: - Medical and other critical applications - Installation with two independent input sources - Installation in distribution without neutral. No need for external battery rack/cabinet Adapt as per your electrical infrastructure Allows a wider choice of battery and possible re-use of existing battery banks Low Mean time to repair (MTTR) Covers no extra space for service maintenance Over 150 electrical parameter are monitored and updated in every 10ms through black box function Allows for effective reduction of the battery re-charging time and increases its ability to manage long run times Compatible with most of the advanced communication platform including SNMP, MODBUS etc Intuitive LCD equipped with superior feature tracks multiple parameter simultaneously including efficiency graph etc